High-throughput Autoclave FLS-1000

 

High-throughput Autoclave FLS-1000

High-throughput Autoclave

FLS-1000

High-throughput Autoclave FLS-1000

With an improved capacity and user-friendly design, the TOMY Autoclave FLS-1000 makes large volume sterilization easier and accommodates unique shaped articles like bioreactors, fermenters and animal cages. The FLS-1000 also supports you for secure sterilization in compliance with your facilities’ guidelines and global standards like GLP / GMP.

FLS-1000 Large Capacity 100L Wide Chamber 45cm

User Friendly and Safety Features

High-throughput Liquid Sterilization

Do you have any experience that flasks and bottles can not be accommodated as desired when you sterilize a large amount of liquid such as culture media and solvents? The FLS-1000 has a large chamber dimension of 45cm so that it can accommodate 5L × 4 flasks easier with a option flask stand and 500ml × 17 bottles with a standard stainless basket.

FLS-1000 can accommodate 5L × 4 flasks easier with a option flask stand and 500ml × 17 bottles with a standard stainless basket

More Secure Sterilization considering Heat Transfer Time Lag

Sterilization setting time = Sterilization time + Heat transfer time lag

There is Heat Transfer Time Lag when using the steam autoclave. The display shows the ambient temperature inside the chamber, but the temperature of articles to be sterilized arrives later than the display temperature. This is called “Heat Transfer Time Lag“.
For more secure sterilization, it is recommended to add the Heat Transfer Time Lag to the sterilization time.

OptionAutomatically timer countdown by sample temperature w / External Temperature Sensor

The TOMY Autoclave FLS-1000 can check the temperature of articles to be sterilized with an optional External Temperature Sensor. The detected temperature by the External Temperature Sensor can be used to count down the sterilization time (e.g. 20 min.) . That means sterilization will be done with the temperature of articles inside the chamber automatically without calculating Heat Transfer Time Lag manually by yourself.
The detected temperature also works to open the lid safely after sterilization. The lid can be opened after the temperature of articles drops down* and it prevents the sudden boiling of liquid sample.
These features help you to save your time to decide the sterilization time and to reduce troubles of spillage for media or solvent.

  • * 
    The temperature to release the lid interlock can be changed.

OptionPrinter supporting to keep Sterilization Log

Do you have any experience that you were worried if the sterilization was performed as set when you use a shared autoclave in a remote wash room or an autoclave room?
The Optional Printer can print out the operating parameters, chamber temperature, chamber pressure, temperature of articles to be sterilized * and sterilization cycle process.

  • * 
    In using the optional external temperature sensor
Printer supporting to keep Sterilization Log

Secure Sterilization

StandardFine Pressure Adjustment

Secure Sterilization condition is created by saturated steam that temperature and pressure keep the balance for a certain time.
The FLS-1000 heats water in the chamber and create steam. The generated steam is discharged with air from the chamber to approach the saturated steam condition.
When air remains in the chamber, the balance of temperature and pressure breaks and it makes pressure rise.
Fine Pressure Adjustment monitors temperature and pressure,works automatically to remove residual air from the chamber, and adjusts pressure to approach ideal condition for more effective sterilization.

  • * 
    Illustrations are based on images of other models.
Fine Pressure Adjustment

Time-saving

Cooling Fan System

StandardCooling Fan System

The FLS-1000 is standard-equipped with a dual-fan cooling system, shortening overall operation time. The Cooling Fan System reduces cooling time by 60 min.* compared to non-fan operation. It will save your time and give you more to focus on other things.

Cooling Fan Display

  • * 
    In the case of FLS-1000 under the test condition of no load operation, room temperature 25 ℃, sterilizing water 6 liters and power input AC200V 18A.

Perfect Height Design

Easy loading / unloading of the articles
Easily-accessible chamber allows easy cleaning

Perfect Height Design
Comparison with TOMY SX models

Safety Lid Opening Design (Avoiding Steam)

FLS-1000 is designed to avoid steam from the chamber. So, operator opens the lid without steam contact.

Safety Lid Opening Design (Avoiding Steam)

Mechanically-assisted Lid & Foot Pedal

A top-open lid, which can be operated easily with a single hand and a single foot, is provided. To open the lid, the lid lock is released by stepping on the foot pedal locates at the bottom while pressing the lid down. The lid can be opened with minimal effort owing to mechanical assistance. In addition, the lid can be closed easily just by pressing it down.

Mechanically-assisted Lid & Foot Pedal

Intuitive Display

  • The LED display shows working status visually.
  • Swivable control panel for install location.
  • Sterilization can be selected from 3 courses.
  • (Sterilization, Liquid Sterilization, Memory)

Intuitive Display

  • * 
    The illuminated display on the operating panel shown in the picture
    is different from the actual display at the time of operation.

Easy Water Level Check with Water Level Indicator

Water level indicator of the chamber bottom plate allows operator to check the appropriate water level in the chamber visually and prevent the articles from soaking in sterilizing water.

Water Level Indicator

Easy Water Level Check with Water Level Indicator

Steam Trap Water Alert

The exhaust tank turns on red when water should be drained.

Steam Trap Water Alert

User-friendly Basket, Bucket and Long Basket

“Double handle” is provided which keeps stability of large caliber basket and bucket.
Bottom up designed basket prevents from soaking in sterilizing water.
Stackable protrusion shape

  • Basket ACA-1100B
    StandardOptionBasket
    ACA-1100B
  • Bucket ACA-1000KS
    OptionBucket
    ACA-1000KS
  • Long Basket ACA-1000TP
    OptionLong Basket
    ACA-1000TP

Full Package for High-throughput Autoclave FLS-1000

  • High-throughput Autoclave

    FLS-1000

    High-throughput Autoclave FLS-1000
  • Option

    Flask Stand

    for 5L × 4 flasks

    Flask Stand for 5L × 4 flasks
  • Option

    External Temperature
    Sensor

    External Temperature Sensor

  • One-touch coupler (Installed)

    <Installed>

  • One-touch coupler (Not in use)

    <Not in use>

  • One-touch coupler (Covered)

    <Covered>

One-touch coupler for installation of the temperature sensor for articles to be sterilized and the external temperature sensor.
The sensors can be removed from or installed in the FLS-1000 by the use of the coupler.

  • * 
    This document is created in the PDF file format.
  • * 
    To view PDF files, Adobe Reader or other software is needed.