Low Speed Bench-top Centrifuge LCX-200 / 100

 

Low Speed Bench-top Centrifuge LCX-200 / 100

Low Speed Bench-top Centrifuge

LCX-200 / 100

Low Speed Bench-top Centrifuge LCX-200 / 100

Wide Variety of Rotors

A wide variety of tubes and plates, such as 1.5 / 2.0 ml microtubes, 15 / 50ml conical tubes, blood collection tubes, micro / deep well plates, 250ml bottles, etc., and angled and swing out type rotors are available in three models to suit your application.
  • Swing Out Rotors

    From micro tubes to 250ml bottles.
    • Swing Out Rotor TS-38C
      TS-38C
      Bucket B438,
      Tube Rack 3850-04P
      Conical 50ml × 16
      Conical

      Conical 50ml

    • Swing Out Rotor TS-7C
      TS-7C
      Bucket 7115-08
      Conical 15ml × 32
    • Swing Out Rotor TS-33C
      TS-33C
      Bucket B433
      250ml × 4
      Bucket Cap Kit B433 HS
    • Swing Out Rotor TS-41C
      TS-41C
      Deepwell
      plate × 4
  • Angle Rotors

    Spinning maximum 10,000rpm (Angle rotors only).
    • Angle Rotor CA-16
      CA-16
      Conical 50ml × 8
      10,000 rpm
      11,740 G
    • Angle Rotor CA-5
      CA-5
      2ml × 24
      10,000 rpm
      9,390 G
    • Angle Rotor CA-14HS
      CA-14HS HS
      50ml / 14ml × 4
      10,000 rpm
      8,500 G (50ml)
      7,720 G (14ml)
    • Angle Rotor CA-15
      CA-15
      2ml × 18 or 0.5ml / 0.2ml × 12
      10,000 rpm
      8,500 G (2ml)
      6,600 G (0.5ml)
      5,810 G (0.2ml)
HS This bucket, which has been tested and certified by the Health Protection Agency (HPA, UK) to be compliant with the International Standard (Annex AA of the IEC 61010-2-020), meets requirements for biohazard safety. HS It adopted a hermetically sealed structure equivalent to HS bucket or rotor designed and tested in accordance with the International Standard (Annex AA of the IEC 61010-2-020) to offer excellent sealing performance.

Swing Out Rotors Compatibility

CS-1 TS-4C TS-7C TS-33C TS-38C TS-41C
Max.
10,000rpm
Max.
1,800rpm
Max.
5,000rpm
Max.
5,000rpm*1
Max.
4,200rpm
Max.
4,500rpm
LCX-100 2 ml
10,000rpm
Microplates Ο Ο
LCX-200 Ο Ο Ο Deepwell
Plates
  • * 
    Fixed angle rotors are available for all models.
  • * 
    The above specifications show the maximum value of sped (rpm). These values may change according to the combination of rotor, bucket, adapter and tubes.
  • *1 
    LCX-100: Max.4,100rpm

Rotors & Accessories
Selection Guide

User Friendly and Safety Features

Mix Bucket & Mix Rack & Multi Rack

  • when 15ml tubes and 50ml tubes load to swing out rotor
    Previous

    1 set of 15ml tube bucket / rack and 1 set of 50ml tube bucket / rack were required.
    Previous image
    Mix Bucket
    &
    Mix Rack
    Mix bucket / Mix rack can be loaded 15ml tube and 50ml tube mixed together.
    Mix bucket / Mix rack can be loaded 15ml tube and 50ml tube mixed together.
  • Bucket for TS-7C Swing Out Rotor
    Bucket 7M5015-1 for Swing Out Rotor TS-7C
    7M5015-1
    (Mix Bucket)
    (50ml × 1tube + 15ml × 4tubes) × 4
    Mix bucket can be loaded 15ml tube and 50ml tube mixed together.
    Mix bucket can be loaded 15ml tube and 50ml tube mixed together.
    50ml=50ml 15ml=15ml
    Rack for TS-38C Swing Out Rotor
    38M-TC0204P
    (Mix Rack for Conical Tubes)
    50ml × 2tubes × 4 or 15ml × 4tubes × 4
    Rack 38M-TC0204P for Swing Out Rotor TS-38C
    For example, Mix rack can be used(50ml × 1tube +15ml × 2tubes) × 4!
    For example, Mix rack can be used(50ml × 1tube +15ml × 2tubes) × 4!
    50ml=50ml 15ml=15ml
    3810M-14P
    (Multi Rack for Blood Collection Tubes)
    5 to 10ml × 14tubes × 4

    Rack 3810M-14P for Swing Out Rotor TS-38C

Flex-Spin System for safer and more efficient operation

Innovative Flex-Spin System employed to maintain safe and efficient centrifugal operation allows a margin of error and eye-balancing of sample tubes.
  • * 
    Some rotors are excepted.

 

  • LCX-200 / 100 are equipped with a function to automatically reduce the rotation speed and shut the system down if it is being run over the imbalance tolerance limit.
  • Flex-Spin Drive

    Flex-Spin Drive features a flexible motor shaft that equalizes minor imbalances without damaging the centrifuge or triggering the imbalance protection system. This allows excellent tolerance for minor differences in sample volumes.
  • One-push rotor locking knob

    With a single knob push, the rotor can be quickly and securely fixed.

    • * 
      Some rotors are excepted.
    • To mount the rotor

      Pressing the red snap on the locking knob down

      Place the locking knob on the shaft and secure the rotor to the shaft by pressing the red snap on the locking knob down the shaft until it “clicks”.
    • To dismount the rotor

      Pull the locking knob out from the shaft

      Pull the locking knob out from the shaft, while holding down the red snap on the top.

Intuitive Display and Control Panel

LCD monitor display
Easy-to-see LCD monitor display shows various information including remaining run time, error messages, rotor types in use and records of centrifugal operation.
  • * 
    Indication displays on the control panel in the photo is different from displays of actual operation.
Dual color LED display allows the user to monitor the operation status just by looking the display
Dual color LED display allows the user to monitor the operation status just by looking the display; red indicates that the rotor is spinning while green indicates the rotor is stopped.

Three-step acceleration and three-step and natural deceleration

  • Three-step acceleration and three-step and natural deceleration
  • Initial values for acceleration and deceleration characteristics are set from 0 to 500rpm, however, they can be varied up to maximum speed in 100rpm increments by function settings.

Convenient Flashing Function

For quick spin-down.

Specifications

Model LCX-200 LCX-100
Low Speed Bench-top Centrifuge LCX-200 Low Speed Bench-top Centrifuge LCX-100
Maximum Speed 10,000rpm
Maximum RCF 11,740G
Maximum Capacity 1,000ml (250ml × 4)
Speed Control System Microprocessor feedback control
Drive Motor Induction motor
Drive System Flex-Spin drive system (Direct drive with an automatic alignment function)
Data Entry Jog Dial equipped with an <ENTER> button
Speed Setting Range 100rpm to 10,000 rpm (100rpm increments)
RCF Setting Range 10 G to 11,740 G (Less than 300G : 10G increments, Over 300G : 100G increments)
Time Setting Range From 10 sec to 50 sec, in 10 sec increments,
from 1 min to 99 min, in 1 min increments or <F-> for free
Safety Devices Imbalance detector, Lid interlock, Lid open / close detector, Abnormal speed detector, Over-current
circuit breaker, Rotor identification system, Motor over-current detector.
Additional Functions Three-step acceleration characteristics selection, Three-step deceleration characteristics selection,
Three memory function, FLASH (momentary spin) function, BART Code selection,
Memory function for last run parameters.
Rated Current 120V : 10A
220-240V : 6A 220-240V : 4A
Power Requirements 1-Phase AC120V 60Hz 15A
1-Phase AC220-240V 50 / 60Hz 8A 1-Phase AC220-240V 50 / 60Hz 8A
Power Consumption (Heat output) 660W (568kcal / h) 430W (370kcal / h)
Breaker Rated breaking current 120V : 15A
Rated breaking current 220-240V : 7.5A Rated breaking current 220-240V : 7.5A
Protection Against Electric Shock Class I
Dimensions (excluding hinge) 460W × 584D × 355H mm 430W × 554D × 355H mm
Net Weight 41kg 39kg
Environmental Requirements Ambient temperature range:6 to 35℃, Relative humidity:not exceeding 75%RH,
Altitude: up to 2000m, Intended exclusively for use indoors,
overvoltage category:II, pollution degree:2, inclination:not exceeding 2 degrees
Accessories Included Operator’s manual × 1copy, BART Code table × 1pc, Clear storage case for operator’s manual × 1pc, Rotor locking knob × 1pc, Power cord × 1pc, Digital Warranty Information × 1copy, Inspection sheet × 1copy.
  • * 
    The above specifications show the maximum value of speed, RCF (G) and sample capacity. These values may change according to the combination of rotor, bucket, adaptor and tubes.

  • * 
    This document is created in the PDF file format.
  • * 